Plate 18: Pumping diagram "Pressure"

     

   
PLATE 18 - PUMPENPLAN "DRÜCKEN"
Pumping diagram "Pressure"
     
     
  Translation of the first 5 columns of the table:   Translation of the key at the right of the table      
 
Ser.
Designation
Units for
Type of
Performance of
 
No.
of the pumps
1 Ship
Pump
the pump m³/hour
  1 Main drain pump (P)
1
Centrifugal
parallel: 120
         
series:  40
  2 Auxiliary drain and trim P
1
Piston
110V:   18
         
170V: 215
  3 Auxiliary drain P 1
1
Centrifugal
15
  4 Auxiliary drain P 2
1
Centrifugal
15
  5 Portable hand emergency drain P
1
Hand piston
~8.3
  6 Hand drain P (for periscope shaft)
1
Vane
1.2
  7 Cooling water P stb. & port
2
Piston
92.5
  8 Cooling E-motor room P
1
Centrifugal
   110V: 20
         
   170V: 31.5
  9 Spare cooling water P
1
Centrifugal
   110V: 70-75
         
   170V: 130
  10 Cooling water P
 
        Compressor 1
1
Centrifugal
---
        Compressor 2
1
Vane
---
  11 Hand cooling water P
1
Hand piston
~6.24
  12 Hand emergency drinking water P 1
1
Vane
1.8
  13 Hand emergency drinking water P 2
1
Vane
1.8
  14 Lubricating oil P stb. & port
2
Geared
59
  15 Spare lubricating oil P
1
Axial flow
110V: 48
         
170V: 55
  16 Hand lub. oil P
1
Hand piston
~4.2
  17 Hand dirty lubricating oil P
1
Vane
2.8
  18 Dirty lub. oil P
1
Geared
0.5
  19 Fuel oil forwarding P
2
Geared
2.0
  20 Hand drinking water P
1
Hand piston
~2.88
  21 Hand distillate P fresh water gen.
1
Vane
1.2
22 Hand brine P fresh water generator
1
Hand piston
1.6
  23 Main and auxiliary hydraulic oil P
2
Axial flow
4.5
  24 Circulation P heating steam gen.
1
Centrifugal
12
  25 Feed P heating steam gen.
1
Centrifugal
0.3
  26 Hand filling P heating steam gen.
1
Vane
2.0
  27 Clean lubricating oil P
1
Geared
0.5
  28 Lub. oil turbocharger P stb. & port
2
    ---
---
  29 Cooling P gyro-compass
1
    ---
---
   
   
   
Lichtweite after the pump
Inner diameter just after the pump [in mm]
 
Lichtweite am Rohr austritt
Inner diameter at the pipe exit [in mm]
   
  Es bedetet ferner
  It means further
   
Lichtweite after der Pumpe
  Pump presses through fixed line
   
Pumpe drückt durch feste Leitung und über Schlauchverbindung
  Pump presses through fixed line and hose connection
   
Pumpe drückt über Schlauchverbindung
  Pump presses through a hose connection
   
Pumpe drückt über Kühlwasser Hochbehälter
  Pump presses through cooling water header tank
   
   
   
Fällt ab Werk Nr. 1035 fort
  Discontinued from Work No. 1035 onwards
 
     
 
Insert in the center at the bottom of the table
  Hand wash water P 1
1
Vane
1.2
Presses to wash water tank 1
  Hand wash water P 2
1
Vane
1.2
Presses to wash water tank 2
  Hand wash water P 2
1
Vane
2.4
Presses to the shower or WC 3