Plate 15: Main drainage system

     

   
PLATE 15 - HAUPT LENZANLAGE
Main drainage system
     
 
a HAUPT LENZEN. . .  zB HECKTORPEDORAUM
  Main drain suction valve. . . for example stern torpedo room
   
a1 LENZEN TRIEBÖLBUNKER
  Drain valve for fuel oil bunker
   
a2 LENZEN TRINKWASSER ZELLEN
  Drain valve drinking water tanks
   
b ENTLÜFTEN HAUPT LENZLEITUNG
  Vent valve main drain line
   
c VERBINDUNG HAUPT und HILFS LENZLEITUNG. . . zB HECKTORPEDORAUM
  Connection, main and auxiliary drain line. . .  for example, stern torpedo room
   
d EINTRITT HAUPT LENZPUMPE
  Intake valve main drain pump
   
   
   
   
e LENZAUSTRITT HAUPT LENZPUMPE
  Drain discharge valve main drain pump
   
f VON SEE INNEN LENZPUMPEN
  Innner valve from sea drain pumps
   
g BORDVENTIL NACH SEE LENZPUMPEN
  Hull valve to sea drain pumps
 
g1 NACH SEE INNEN LENZPUMPEN
  Inner valve to sea for drain pumps
   
h BORDVENTIL LENZDRUCKANSCHLUẞ TAUCHZELLE 5 STEUERBORD
  Hull valve drain pressure connection to starboard ballast tank 5
   
h1 HAUPT LENZANSCHLUẞ HINTEN bzw VORN
  Main drain connection aft and forward
   
h2 HAUPT LENZSAUGEANSCHLUẞ
  Main drain connection connection
   
h3 SAUGEANSCHLUẞ REGELZELLEN
  Suction connection regulating tanks
   
h4 DRUCKANSCHLUẞ REGELZELLEN
  Pressure connection regulating tanks
   
h5 AUSDRÜCKANSCHLUẞ REGELZELLEN
  Blowing connection regulating tanks