Plate 17:  Flooding- venting- and blowing system for regulating and negative tanks

     

   
PLAN 17 - ANBLASE und NOTAUSBLASEEINRICHTUNG, AUSDRUCKLEITUNG REGEL und UNTERTRIEBZELLEN (EINBAUGLEICH GESEHEN)
Flooding- venting- and blowing system for regulating and negative tanks (as installed)
     
 
a BORDVENTIL ANBLASEN. . . zB TAUCHBUNKER 2 BACKBORD
  Hull valves in blow lines. . . for example, main ballast and reserve fuel oil tank 2 port
   
b ANBLASEVENTIL. . . zB TAUCHZELLE 3 BACKBORD
  Individual tank blow valves. . . for example, ballast tank 3 port
   
b1 HAUPT ANBLASE TAUCHZELLE
  Master blowing valve for ballast tanks
   
b2 ERSATZ ANBLASEVENTIL TAUCHZELLE
  Auxiliary blowing valve for ballast tanks
   
c AUSDRÜCKVENTIL. . . zB REGELZELLE STEUERBORD 2
  Blowing valves. . . for example, for regulating tank starboard 2
   
c1 HAUPT AUSDRÜCKVENTIL. . . zB REGELBUNKER BACKBORD 1
  Main blowing valve. . .  for example, regulating and reserve fuel oil tank port 1
   
d ANSCHLUẞ. . . zB AUSDRÜCKVERTRILER
  Connection. . . for example, blowing manifold
d1 NOTAUSBLASEANSCHLUẞ BACKBORD bzw STEUERBORD
  Emergency blowing connection, port or starboard
   
d2 TAUCHERANSCHLUẞ NOTLUFT
  Diver's connection, emergency air
   
d3 AUSDRÜCKANSCHLUẞ. . . zB REGELZELLE STEUERBORD 2
  Blowing connection. . . fir example, tank starbord 2
   
e HAUPT NOTAUSBLASEVENTIL
  Main emergency blowing valve
   
f NOTAUSBLASEHAHN. . . zB TAUCHBUNKER 4 BACKBORD
  Emergency blowing cock. . . for example, main ballast and reserve fuel oil tank 4 port
   
g BORDVENTIL NOTAUSBLASEN. . . zB TAUCHZELLE 1
  Hull valves, emergency blowing (operable from above and below pressure hull). . . for example, ballast tank 1
   
h ENTWÄSSERN. . . zB AUSDRÜCKVERTEILER REGELZELLE 2
  Drain. . . for example, for blowing air distributor, regulating tank 2
   
i ENTLÜFTEN UNTERTRIEBZELLE. . . zB BACKBORD
  Hull valves for venting diving (negative buoyancy) tanks. . . for example, port